On the Routine Use of Soft X-Rays in Macromolecular Crystallography, Part III- The Optimal Data Collection Wavelength
|
OverviewOverview
Complete and highly redundant data sets were collected at different wavelengths between 0.80 and 2.65 A for a total of ten different protein and DNA model systems. The magnitude of the anomalous signal-to-noise ratio as assessed by the quotient R(anom)/R(r.i.m.) was found to be influenced by the data-collection wavelength and the nature of the anomalously scattering substructure. By utilizing simple empirical correlations, for instance between the estimated deltaF/F and the expected R(anom) or the data-collection wavelength and the expected R(r.i.m.), the wavelength at which the highest anomalous signal-to-noise ratio can be expected could be estimated even before the experiment. Almost independent of the nature of the anomalously scattering substructure and provided that no elemental X-ray absorption edge is nearby, this optimal wavelength is 2.1 A.
About this StructureAbout this Structure
2A7C is a Single protein structure of sequence from Sus scrofa with , and as ligands. Active as Pancreatic elastase, with EC number 3.4.21.36 Full crystallographic information is available from OCA.
ReferenceReference
On the routine use of soft X-rays in macromolecular crystallography. Part III. The optimal data-collection wavelength., Mueller-Dieckmann C, Panjikar S, Tucker PA, Weiss MS, Acta Crystallogr D Biol Crystallogr. 2005 Sep;61(Pt 9):1263-72. Epub 2005, Aug 16. PMID:16131760