6wx6: Difference between revisions
No edit summary |
No edit summary |
||
Line 12: | Line 12: | ||
== Function == | == Function == | ||
[[http://www.uniprot.org/uniprot/FRIL_HUMAN FRIL_HUMAN]] Stores iron in a soluble, non-toxic, readily available form. Important for iron homeostasis. Iron is taken up in the ferrous form and deposited as ferric hydroxides after oxidation. Also plays a role in delivery of iron to cells. Mediates iron uptake in capsule cells of the developing kidney (By similarity).<ref>PMID:19923220</ref> <ref>PMID:20159981</ref> | [[http://www.uniprot.org/uniprot/FRIL_HUMAN FRIL_HUMAN]] Stores iron in a soluble, non-toxic, readily available form. Important for iron homeostasis. Iron is taken up in the ferrous form and deposited as ferric hydroxides after oxidation. Also plays a role in delivery of iron to cells. Mediates iron uptake in capsule cells of the developing kidney (By similarity).<ref>PMID:19923220</ref> <ref>PMID:20159981</ref> | ||
<div style="background-color:#fffaf0;"> | |||
== Publication Abstract from PubMed == | |||
Blotting times for conventional cryoEM specimen preparation complicate time-resolved studies and lead to some specimens adopting preferred orientations or denaturing at the air-water interface. Here, it is shown that solution sprayed onto one side of a holey cryoEM grid can be wicked through the grid by a glass-fiber filter held against the opposite side, often called the `back', of the grid, producing a film suitable for vitrification. This process can be completed in tens of milliseconds. Ultrasonic specimen application and through-grid wicking were combined in a high-speed specimen-preparation device that was named `Back-it-up' or BIU. The high liquid-absorption capacity of the glass fiber compared with self-wicking grids makes the method relatively insensitive to the amount of sample applied. Consequently, through-grid wicking produces large areas of ice that are suitable for cryoEM for both soluble and detergent-solubilized protein complexes. The speed of the device increases the number of views for a specimen that suffers from preferred orientations. | |||
Through-grid wicking enables high-speed cryoEM specimen preparation.,Tan YZ, Rubinstein JL Acta Crystallogr D Struct Biol. 2020 Nov 1;76(Pt 11):1092-1103. doi:, 10.1107/S2059798320012474. Epub 2020 Oct 13. PMID:33135680<ref>PMID:33135680</ref> | |||
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.<br> | |||
</div> | |||
<div class="pdbe-citations 6wx6" style="background-color:#fffaf0;"></div> | |||
==See Also== | ==See Also== |